In your example several items appear to be non compliant especially the lack of an equipment grounding conductor for the exhaust fan.
Nec bathroom exhaust fans.
The homewerks worldwide ventilation fan features an integrated the homewerks worldwide ventilation fan features an integrated bluetooth enabled stereo speaker and an led light.
Ft requires an exhaust fan.
Surprisingly bathroom fans are not required by some building codes.
Gfcis are electrocution prevention devices that are designed to shut off the power supply to the bathroom fan in less than a second if there is an interruption in power.
Each bathroom should have a circuit for lighting and an exhaust fan according to the code this circuit may be a 15 amp circuit if it serves just lighting but it should be a 20 amp circuit if it is also serving a vent fan.
For quick reference a 50 square foot bathroom needs a 50 cfm fan.
The model building codes adopted by most jurisdictions typically require bathroom ventilation to be provided either by an operable window 3 sq.
There are wall mount exhaust fans as well as ceiling exhaust fans.
Another consideration to think about is the placement of your fan.
Perfect for the tech savvy homeowner with a desire to stream audio from their smartphone or tablets into their bathroom.
If you have a bathroom with a separate enclosed toilet you ll also need an additional fan for that space.
Bathroom ventilation requirements summary.
General lighting fan circuit required.
All municipalities have different requirements but some do not draw a hard line on requiring exhaust fans.
Important nec bathroom regulations.
Every bathroom without an openable window min 1 5sq.
Proper bathroom vent exhaust fan placement becomes critical if you have any sources of hot moist air in the bathroom area tub shower steam room etc and the best strategic vent location would be directly above or as close as possible to that source but still high up.
The bathroom ceiling exhaust or wall should be discharging to the house exterior not into the ceiling wall frame cavity or another room crawlspace attic etc.
This is especially true if they are located inside of a shower or bathtub enclosure.
Some appliances such as bathroom exhaust fans can include a requirement in the instructions to be gfci protected and this must be followed as stated in 110 3 b.
Bathroom code does address the issue of moving odor and moisture laden air from the bathroom to the outside.
Or greater or by mechanical means a bathroom vent fan 20 continuous or 50 cfm intermittent vented to the building exterior.